Figure 18. Typical Connector Dimensions
CONNECTOR ACCESSORIES - NAS1599

Installation and Repair Practices Volume II Aircraft Circular Connectors and Accessories
Page Navigation
  997    998    999    1000    1001  1002  1003    1004    1005    1006    1007  
img
NAVAIR 01-1A-505-2
011 02
TO 00-25-255-1
Page 18
TM 1-1500-323-24-2
97. CONNECTOR REMOVAL AND INSTALLATION.
98. CONNECTOR BUILD-UP, SOLDER CON-
If the connector is severely damaged or cannot be
TACTS.
repaired using the above procedures, proceed as
follows:
99. For build-up procedures for solder contacts refer to
NAVAIR 01-1A-505-1, WP 016 00.
a.  Starting from outside of damaged connector,
tag wires and remove all contacts from connector
100.
CONNECTOR CLEANING AND PRESER-
(Paragraph 93). If contact cannot be removed, cut wire
VATION.
as close to connector as possible and attach new contact
(Paragraphs 87 and 88).
101.
For connector cleaning and corrosion control
procedures refer to NAVAIR 01-1A-505-1, WP 026 00.
b.  Starting from center of new connector, insert
contact into correct cavity (Paragraph 89). Remove tag
from wire. Repeat procedure until all contacts are
installed in new connector.