NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
003 02
1 September 2011
Page 33
19. Connectors M24308/4. The M24308/4 connectors
illustrated (Figure 14).
are class G, general purpose plugs with removable crimp
type pin contacts. For insert arrangements refer to Figure
30. CONTACTS. The type of contacts used on this
4.
type connector are as follows:
20. Connectors M24308/5. The M24308/5 connectors
a. Solder contacts. Solder contacts are non-
are class N, nonmagnetic receptacles with solder type
removable from the insert and have either eyelet or
socket contacts. For insert arrangements refer to Figure
solder cup terminals. For solder contact build up refer to
5.
NA01-1A-505-1, WP 016 00. The solder cups are so
designed that during soldering, no components will be
21. Connectors M24308/6. The M24308/6 connectors
damaged and no liquid solder shall escape.
are class N, nonmagnetic receptacles with removable
crimp type socket contacts. For insert arrangements refer
b. Crimp removable contacts. Removable crimp
to Figure 6.
contacts M24308 have been superseded by M39029
contacts listed in Table 2.
22. Connectors M24308/7. The M24308/7 connectors
are class N, nonmagnetic plugs with solder type pin
c. Insulation Displacement Contacts (IDC). IDCs'
contacts. For insert arrangements refer to Figure 7.
are non-removable and accommodate 28 AWG stranded
round conductor flat cable with conductors on .O50 inch
23. Connectors M24308/8. The M24308/8 connectors
(1.27 mm) centers.
are class N, nonmagnetic plugs with removable crimp
contacts. For insert arrangements refer to Figure 8.
31.
CONNECTOR BUILDUP.
24. Connectors M24308/9. The M24308/9 connectors
32. WIRE STRIPPING. Strip wire in accordance
are class H, hermetic plugs with solder type and eyelet
with following procedure:
type pin contacts. For insert arrangements refer to Figure
9.
a. Cut wire to proper length. Ensure enough wire
remains for adequate strain relief without leaving excess
slack.
25. Connectors M24308/23. The M24308/23 are
b. Strip insulation from end of wire, remove 3/16 to
contacts. For insert arrangements refer to Figure 10.
15/64 in. of insulation (NAVAIR 0l-IA-505-1, WP 009
00). Select contact (Figures 1 thru 13).
26. Connectors M24308/24. The M24308/24 are plugs
with straight and 90 printed circuit board socket
33. CONTACT CRIMPING. Crimp contact in
contacts. For insert arrangements refer to Figure 11.
accordance with following procedure:
27. Connectors M24308/27. The M24308/27 are non-
a. Select correct crimp tool (Table 2).
insulation displacement socket contacts. For insert
b. Perform die closure check, install positioner, and
arrangements refer to Figure 12.
set selector knob for gage of wire (NAVAIR 01-1A-505-
1, WP 013 00).
28. Connectors M24308/28. The M24308/27 are non-
c. Insert stripped wire into contact conductor barrel.
insulation displacement socket contacts. For insert
Ensure all wire strands are inside contact conductor
arrangements refer to Figure 13.
bane1 and visible in contact inspection hole (Figure 16).
29. INSERT CONFIGURATION. The insert
d. Crimp contact to wire.
configuration is the manner in which contacts are placed
within insert in a standard configuration. All
arrangements identified in Figures 1 through 13 are