NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
014 02
1 September 2011
Page 52
1. For non-environmental contact
0.787"
(620175050 and 620075050) slide alignment
(20 mm)
boot over cable. For environmental contact
(617175051 and 617075051) slide alignment
boot equipped with its sealing boot over
cable. Be careful to not damage the sealing
boot while sliding it on the cable jacket.
Alignment
2. Strip outer cable jacket to dimensions
Boot
shown, IAW NAVAIR 01-1A-505-1 WP 009
00.
Cable Jacket
3. Slide ferrule on the cable till butted against
cable jacket.
Ferrule should slide
over cable jacket and
butt at the end of the
Cable Jacket
jacket.
4. Comb out exposed shield braid and cut the
rod fillers.
Shield
Combed
Ferrule
Shield
0.157"
4.0 mm
Cable
5. Fold combed shield braid over ferrule and
trim to dimension.
6. Trim center conductors to correct length.
7. Strip center conductors to dimensions
Ferrule
shown, IAW NAVAIR 01-1A-505-1 WP 009
Shield
00.
Braid
0.404"
10.3 mm
Center
Conductors
0.502"
12.8 mm
Pin
Center
Center conductor visible in center
Contact
contact inspection hole.
8. Slide center contacts over center
conductors till fully seated. Ensure
Ferrule
conductors are visible in the inspection holes.
9. Crimp center contacts using tools in Table
6 and NAVAIR 01-1A-505-1, WP 013 00.
Note: While pin and socket contacts are
shown here, the assembly will be supplied
with and built with 4 pin or 4 socket contacts. Socket
Center
Contact
Figure 43. 620175050, 620075050,617175051 and 617075051 Quadraxial Contact Buildup (Sheet 1 of 2)