3.
From rear of electrical connection panel, insert pumpage overtemperature connector 1A1J3 (8) through right-hand hole
in panel, position and hold the mounting flange on rear of connector, and install and tighten the four cross tip screws and
flat washers that secure connector 1A1J3 to the module frame.
4.
Connect alternator wires (7) at in-line connectors as tagged.
5.
Connect small electrical wire (6) to starter solenoid as tagged.
6.
Connect electrical wire to oil pressure switch (5) as tagged.
7.
At intake manifold, connect electrical wires to air intake heaters (4) as tagged. Install boots over connectors.
8.
Install electrical wire to engine temperature sensor (3) as tagged.
9.
Connect fuel shutoff solenoid electrical wires (2) at in-line connectors as tagged.
10. Group and route wires of cable assembly W101 in general layout observed at removal, and install tiedown straps as
necessary to secure wiring harness.
11. Tighten cable loop (1).