TM 10-4930-351-14
UNIT MAINTENANCE
ADVANCED AVIATION FORWARD AREA REFUELING SYSTEM MODEL M100A1
REPLACE CIRCUIT BREAKERS CB1 OR CB2
INITIAL SET-UP:
Tools:
Materials/Parts Required:
Screwdriver, Cross Tip, #2
Combination Wrench, 1/2"
REMOVAL
1.
Remove the twenty-four screws (1) and flat washers (2) that secure the control panel (3) to the control box.
2.
Lift the control panel (3) from the control box and set on edge convenient to circuit breaker (5) to be replaced.
3.
Tag and remove the leads (4) attached to the circuit breaker (5).
4.
Remove the nut (6) and lock washer (7) that secure the circuit breaker (5) to the panel. Remove the circuit breaker (5).
INSTALLATION
1.
Install circuit breaker (5) on control panel (3) with key fully engaged. Install and tighten nut (6) and washer (7).
2.
Install leads (4) on circuit breaker (5) as tagged. Remove tags.
3.
Install control panel (3) in control box with twenty-four screws (1) and flat washers (2).
0067 00-1