TM 10-4930-351-14
UNIT MAINTENANCE
ADVANCED AVIATION FORWARD AREA REFUELING SYSTEM MODEL M100A1
REPLACE VOLTAGE REGULATOR
INITIAL SET-UP:
Tools:
Materials/Parts Required:
Screwdriver, Cross Tip, #2
Key, Socket Head Screw, 3/16"
REMOVAL
1.
Remove the twenty-four screws (1) and flat washers (2) that secure the control panel (3) to the control box (4).
2.
Lift the control panel (3) from the control box (4) and set on edge clear of work area.
3.
Tag all voltage regulator leads and remove from voltage regulator (5).
4.
Remove the two socket head screws (6), flat washers (7) and ground wire (8). Remove the voltage regulator (5).
INSTALLATION
1.
Install voltage regulator (5) and ground wire (8) in control box (4) with two socket head screws (6) and flat washers (7).
2.
Install leads on voltage regulator (5) as tagged. Remove tags.
3.
Install control panel (3) in control box (4) with twenty-four screws (1) and flat washers (2).
0069 00-1