TM 10-4930-351-14
UNIT MAINTENANCE
ADVANCED AVIATION FORWARD AREA REFUELING SYSTEM MODEL M100A1
REPAIR CCR NOZZLE ASSEMBLY
INITIAL SET-UP:
Materials/Parts Required:-Continued
Tools:
Tool Kit, General Mechanic Automotive
Chemical and Oil Protective Gloves
Equipment Condition:
CCR Nozzle removed from fuel system.
Materials/Parts Required:
Compound, Sealing
Compound, Silicone
Dry Cleaning Solvent
DISASSEMBLY
WARNING
Fuels are toxic and flammable. Do not get on person or clothing. Do not use near
open flame. Area should be well-ventilated. Using drycleaning solvents incorrectly
can cause injury or even death. Fuel is flammable. Do not smoke.
Rubber gloves should be worn when handling fueling system components due to the
toxic effects of some fuel additives.
1.
Pull the nozzle collar (1) back to release the cap (2) from the discharge end of the nozzle. Remove the cap (2).
2.
Remove screw (3) holding the ground cable assembly (4) and cap assembly cable to the nozzle housing (5).
3.
Remove strainer body (6) and attached coupling assembly (10) from strainer housing (7).
4.
Remove strainer (8) and preformed packing (9) from strainer housing (7). Discard preformed packing (9).
5.
Place strainer body (6) into a soft face vise.
6.
Unscrew coupling assembly (10) from strainer body (6).
7.
Remove dust cover (11) from coupling half (13).
8.
Remove and discard seal (12) from coupling half (13).
9.
Remove and discard seal (14) from dust cover (11).
0075 00-1