TM 10-4930-351-14
UNIT MAINTENANCE
ADVANCED AVIATION FORWARD AREA REFUELING SYSTEM MODEL M100A1
REPLACE CCR NOZZLE UNISEX COUPLING
INITIAL SET-UP:
Tools:
Equipment Condition:
Tool Kit, General Mechanic Automotive
CCR Nozzle removed from fuel system.
Chemical and Oil Protective Gloves
Materials/Parts Required:
REMOVAL
WARNING
Fuels are toxic and flammable. Do not get on person or clothing. Do not use near
open flame. Area should be well-ventilated. Using drycleaning solvents incorrectly
can cause injury or even death. Fuel is flammable. Do not smoke.
Rubber gloves should be worn when handling fueling system components due to the
toxic effects of some fuel additives.
1.
Remove ball retaining screw (1) and O-Ring (2). Discard O-Ring (2).
2.
Position a wiping rag under the coupling (3) with screw hole oriented toward wiping rag. Push in and rotate unisex
coupling (3) back and forth until all 41 balls (4) have collected in the wiping rag.
3.
Pull unisex coupling (3) from inlet (5).
4.
Remove and discard O-Ring (6) from inlet (5).
5.
Remove and retain spring (7) from unisex coupling.
0076 00-1