TM55-2840-251-23
6-5
FUEL MANIFOLD ASSEMBLY (Continued)
6-5-2 INSTALLATION (Cont)
8.
Install No. 1 manifold adapter in boss on gas
generator case. Align transfer tubes (7) already
installed in adapters at No. 2 and 14 positions and push
into No. 1 adapter.
NOTE
If difficulty is experienced in aligning
transfer tubes, lift adapters at No. 2 and
14 locations, approximately one half inch
away from gas generator case or until
transfer tubes enter No. 1 adapter.
GO TO NEXT PAGE
6-22