TM55-2840-251-23
Section XI FUEL LINES AND FITTINGS
6-11 FUEL LINES AND FITTINGS
This task covers:
a.
Removal (6-11-1)
c.
Inspection (6-11-3)
b.
Cleaning (6-11-2)
d.
Installation (6-11-4)
INITIAL SETUP
Applicable Configurations:
All
Tools:
Powerplant Mechanic's Tool Kit
NSN 5180-00-323-4944
Torque Wrench (O to 500 inch-
pounds)
Materials:
Lockwire (E.5)
Varsol (E.9)
Crocus Cloth (E.41)
Turco Super Carb (E.63)
Personnel Required:
68B Powerplant Mechanic
66G Aircraft Inspector
General Safety Instructions:
WARNING
TOXIC AND FLAMMABLE SOLVENTS
Solvents used for cleaning are toxic and
flammable. They irritate skin and cause
burns. Fire can result from use near
heat or open flame.
Use only in a well-ventilated area. Wear
rubber gloves. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. GET
IMMEDIATE MEDICAL ATTENTION FOR
EYES.
GO TO NEXT PAGE
6-49