TM 55-2840-251-23
Section III IGNITION REGULATOR
7-3 IGNITION REGULATOR
This task covers:
a.
Removal (7-3-1)
b.
Inspection (7-3-2)
c.
Testing (7-3-3)
d.
Repair (7-3-4)
e.
Installation (7-3-5)
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Electrician's Tool Kit
NSN 5180-00-323-4915
Torque Wrench (O to 100 inch-
pounds)
Ignition Test Set (Appendix D)
Materials:
Lockwire (E.4)
Trichlorethane (E.46)
Solder (E.47)
Crocus Cloth (E.64)
Adhesive (E.65)
Parts:
Rivet
Personnel Required:
68F Aircraft Electrician
References:
TM 55-2840-251-23P
General Safety Instructions:
WARNING
TOXIC AND FLAMMABLE SOLVENTS
Solvents used for cleaning are toxic and
flammable. They irritate skin and cause
burns. Fire can result from use near heat or
open flame.
Use only in a well-ventilated area. Wear
rubber gloves. In case of contact,
immediately flush skin or eyes with water
for at least 15 minutes. GET IMMEDIATE
MEDICAL ATTENTION FOR EYES.
GO TO NEXT PAGE
7-9