TM 55-2840-251-23
7-4 IGNITION CABLES (Continued)
7-4-4 INSTALLATION
1.
Install cable (9) at glow plugs (11) and regulator
cover (10). Torque connectors at regulator fingertight
plus five degrees, then lockwire (E.4).
2.
Torque connectors at plugs (11) fingertight plus 45
degrees, then lockwire (E.4).
3.
Install bolts (2), (4), (6) and (8), and nuts (1), (3), (5)
and (7). Torque nuts to 32 to 36 inch-pounds.
FOLLOW ON MAINTENANCE:
None
END OF TASK
7-17/(7-18 blank)