TM 55-2840-254-23
2-10 CLEAN COMPRESSOR BLEED BAND
2-10
INITIAL SETUP
General Safety Instructions:
Applicable Configurations:
All
Tools:
None
Materials:
Dry Cleaning Solvent (E17)
Gloves (E20)
Lint-Free Cloth (E26)
Personnel Required:
68B10 Aircraft Powerplant Repairer
Dry cleaning solvent (E17) is flam-
mable and toxic. It can irritate skin
and cause burns. Use only in well-
ventilated area, away from heat and
open flame. In case of contact, im-
mediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Equipment Condition:
Off Engine Task
Oil Cooler Assembly Removed (Task 8-5)
Interstage Air-Bleed Actuator Removed
(Task 2-1 )
Compressor Bleed Band Removed (Task 2-9)
The bleed band is very thin and bends
easily. Be careful not to kink or bend
it during handling. If kinked or bent,
bleed band must be replaced.
1. Wear gloves (E20). Clean bleed band (1) with
clean lint-free cloth (E26) dampened in dry
cleaning solvent (E17).
2. Remove residue from band ends
with clean, dry
lint-free cloth (E26) after cleaning.
FOLLOW-ON MAINTENANCE:
Inspect Compressor Bleed Band (Task 2-11).
END OF TASK
2-44