TM    55-4920-428-13
e. Install the replacement control or switch and attaching hardware.
f. Solder the wires to the control or switch. Use solder QQ-S-571 (Table 4-2, item 3). (See wiring
diagram, FO-21.)
g. Remove the tags.
h. Rotate control or switch shaft fully counterclockwise.
i. Install the knob, pointer aligned with the most counterclockwise panel marking. Tighten the set
screws.
j. Install the panel. (Ref para 4-41.)
k. Perform the final test. (Ref para 4-42.)
4-27.   Replacement   of   Elapased   Time   Meter.
a. Remove the panel. (Ref para 4-18.)
b. (See fig. 6-3.) Tag and unsolder the wires from the meter (70).
c. Remove the attaching hardware. Remove the meter.
d. Install  the  replacement  meter.  Secure  it  with  the  hardware.
e. Solder the wires to the meter. Use solder QQ-S-571 (Table 4-2, item 3). (See wiring diagram,
FO-21.)
f. Remove  the  tags.
g. Install  the  panel.  (Ref  para  4-41.)
h. Perform the final test and check meter for appropriate time change. (Ref para 4-42.)
4-28.   Replacement   of   NULL   Meter.   (CRC)
a.  Remove  the  panel.  (Ref  para  4-18.)
b.  (See  fig.  6-3.)  Tag  and  disconnect  the  wires  from  the  meter  (59).
c.  Remove  the  attaching  hardware.  Remove  the  meter  and  gasket  (60).
d.  Install  the  gasket  (60)  and  replacement  meter.  Secure  it  with  the  hardware.
e. Connect the wires to the meter and install the nuts and washers. (See wiring diagram  FO-21.)
f.  Remove  the  tags.
g.  Install  the  panel.  (Ref  para  4-41.)
h.  Perform  the  final  test.  (Ref  para  4-42.)
4-29.    Replacement    of    DVM.    (CRC)
a.
b.
c.
d.
Remove the panel. (Ref para 4-18.)
(See  fig.  6-3.)  Remove  the  cover  from  the  rear  of  the  meter  (47).
Remove  the  retainer  from  the  rear  of  the  meter.
Tag and unsolder the wires from the meter.
4-7