TM    55-4920-428-13
Naphtha is combustible and toxic. It can irritate skin and cause burns.
Use only with adequate ventilation, away from open flame. In case of
contact, immediately flush skin or eyes with water for at least 15
minutes. Get medical attention for eyes.
e. Remove the DVM. Use naphtha (Item 5, table 4-2) to loosen adhesive if necessary.
f. Clean old adhesive from the panel. Use naphtha (Item 5, table 4-2).
g. Coat the mating surface of the panel with adhesive (Item 6, table 4-2).
h. Remove  the  cover  from  the  replacement  meter.
i. Place  retainer  on  the  replacement  meter.  Secure  the  retainer  to  the  panel  with  the  hardware.
j. Solder the wires to the meter. Use solder QQ-S-571 (Item 3, table  4-2). (See  wiring  diagram,
FO-21.)
k. Remove the tags.
l. Install  the  cover  on  the  rear  of  the  meter,
m. Perform the power supply and DVM tests. (Ref para 4-40.)
n. Install the panel. (Ref para 4-41.)
o. Perform the final test. (Ref para 4-42.)
4-30.   Replacement   of   Power   Supply
Circuit   Board   TB6A.   (CRC)
a. (See fig. 6-3.) Remove the panel. (Ref para 4-18.)
b. Remove  the  hardware  attaching  circuit  board  TB6B  (19).  Move  circuit  board  TB6B  as  needed  for
access to terminals of TB6A (18).
c. Tag and unsolder the wires from the terminals of TB6A.
d. Remove  the  attaching  hardware.  Remove  circuit  board  TB6A.
e. Install replacement circuit board TB6A. Secure it with the hardware.
f. Solder the wires to the terminals. Use solder QQ-S-571 (Item 3, table  4-2). (See  wiring  diagram,
FO-21.)
g. Remove  the  tags.
h. install circuit board TB6B. Secure it with the hardware.
i. Install the panel. (Ref para 4-41.)
j. Perform  the  final  test.  (Ref  para  4-42.)
4-8