Figure 22. Unlocking Contact Retention Mechanism of Broken Wire
CONNECTOR ACCESSORIES

Installation and Repair Practices Volume II Aircraft Circular Connectors and Accessories
Page Navigation
  482    483    484    485    486  487  488    489    490    491    492  
img
NAVAIR 01-1A-505-2
006 03
TO 00-25-255-1
Page 20
TM 1-1500-323-24-2
61.
CONNECTOR REMOVAL AND INSTALLA-
TION. If the connector is severely damaged or cannot
be repaired using the above procedures, proceed as
follows:
a.  Starting from outside of damaged connector,
tag wires and remove all contacts from connector
(Paragraph 57). If contact cannot be removed, cut wire
as close to connector as possible and attach new contact
(Paragraphs 51 and 52).
b.
Starting from center of new connector, insert
contact into correct cavity (Paragraph 53). Remove tag
from wire, Repeat procedure until all contacts are
installed in new connector.
CONNECTOR BUILD-UP SOLDER CON-
62.
TACTS.
63.
For build-up procedures for solder contacts refer
to NAVAIR 01-1A-505-1, WP 016 00.
64. CONNECTOR CLEANING AND PRESERVA-
TION.
Figure 23. Broken Wire Contact Removal
65.
For connector cleaning and corrosion control
procedures refer to NAVAIR 01-1A-505-1, WP 026 00.