NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
010 02
1 September 2011
Page 12
A. Cut Cable End Square, Leaving Enough Cable for
Crimp Sleeve
A
Adequate Strain Relief without Excess Slack.
B. Slide Crimp Sleeve over Cable. Using
Coaxial Cable Stripper, Strip Jacket Dimension A from
End And Trim Shield To Dimension B (Table 6) From
B
Jacket.
C
C. Flare Shield. Do Not Comb Out Individual Shield
Strands. Using Sharp Knife, Strip Dielectric to
Dimension C (Table 6).
Dielectric
D. Slide Rear Insulator, Large Diameter First, Over
Seat
Center Conductor. Seat Rear Insulator against
Dielectric.
E. Insert Center Conductor into Center Contact, Trim
Center Conductor As Required To Seat Center Contact
against Rear Insulator. Ensure Center Conductor
Remains Visible In Contact Inspection Hole.
Contact
Inspection
Hole
F. Crimp Center Contact Using Crimp Tool Rear Front
Rear
Front
Frame And Positioner Specified And Selector Insulator
Insulator
Insulator
Knob Setting For Cable.
G. If Front Insulator Is Not Captivated Inside Contact
Body, Slide Front Insulator, Large Inside Diameter
First, Over Center Contact.
Cable
Center
.
Dielectric
Contact
Figure 7. MIL-DTL-26518 Size 12 Shielded Contact Assembly (Sheet 1 of 2)