Figure 7. MIL-DTL-26518 Size 12 Shielded Contact Assembly (Sheet 1 of 2)
Figure 8. MIL-DTL-26518 Size 8 Shielded Contact Assembly (Sheet 1 of 2)

Installation and Repair Practices Volume III - Aircract Rectangular Electrical Connectors and Accessories
Page Navigation
  247    248    249    250    251  252  253    254    255    256    257  
img
NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
010 02
1 September 2011
Page 13
Contact Must Be
Shield
Seated
H. Slide Contact Body over Center Contact Assembly
And Under Shield Until Fully Seated.
I. Arrange Shield As Close To Original Lay As
1/4" to 9/32"
Possible. Slide Crimp Sleeve Over Shield And Obtain
1/4 To 9/32 Inch Dimension. Trim Excess Shield
Ahead Of Crimp Sleeve.
Trim Excess
Shield Strands
Crimp
Sleeve
J. After Correctly Locating Crimp Sleeve,
Crimp Using Tooling Specified In Table 6.
Figure 7. MIL-DTL-26518 Size 12 Shielded Contact Assembly (Sheet 2 )