Table 6. EPXA and EPX B Quadraxial Contacts and Tools
Figure 30. 617131, 617031, 617133 and 617033 Coaxial Contact Buildup

Installation and Repair Practices Volume III - Aircract Rectangular Electrical Connectors and Accessories
Page Navigation
  354    355    356    357    358  359  360    361    362    363    364  
img
NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
014 02
1 September 2011
Page 27
0.189"
0.157"
(4.8 mm)
(4.0 mm)
1. Strip cable to dimensions shown, IAW
0.126"
(3.2 mm)
NAVAIR 01-1A-505-1 WP 009 00.
2. Slide ferrule on the cable.
Shield
3. Fold first shield and remove EMI tape if
Ferrule
combed
Center
installed on cable.
Contact
4. Comb shield.
Bottomed
5. Slide inner conductor in the center contact
until bottomed.
6. Crimp center contact using tools in Table 3
and NAVAIR 01-1A-505-1, WP 013 00.
Outer Contact
Shield
Ferrule
7. Slide outer contact over center insulator.
8. Fold shield over crimping area.
9. Slide ferrule over shield. Ensure the 0.020
inch clearance is maintained during crimping.
10. Crimp ferrule using tools in Table 3 and
NAVAIR 01-1A-505-1, WP 013 00.
11. Rotate contact in crimping tool 45 and
make a second crimp on the ferrule.
0.020"
12. Insert contact into connector insert using
0.5mm
tools in Table 3.
Figure 29. 617130 and 617030 Coaxial Contact Buildup