1. Strip cable to dimensions shown, IAW
(4.5 mm)
NAVAIR 01-1A-505-1 WP 009 00.
Center
Ferrule
2. Slide inner conductor in the center contact.
0.012"
Contact
3. Solder center contact in accordance with
0.3 mm
Spacing
NAVAIR 01-1A-505-1, WP 016 00. Ensure
0.012 inch dimension is maintained between
center contact and center insulator.
4. Slide outer contact body over center
Outer Contact
contact until bottomed.
Shield
Ferrule
5. Slide ferrule into the outer contact.
Solder
6. Solder outer contact, ferrule and cable in
accordance with NAVAIR 01-1A-505-1, WP
016 00. 7. Insert contact into connector insert
using tools in Table 3.
Figure 31. 617135 and 617035 Coaxial Contact Buildup
Ferrule
0.154"
(3.9 mm)
1. Strip cable to dimensions shown, IAW
NAVAIR 01-1A-505-1 WP 009 00.
Ensure chamfer is
away from end of wire.
Center
Ferrule
2. Slide inner conductor in the center
0.012"
Contact
0.3 mm
contact.
Spacing
3. Solder center contact in accordance
Solder
with NAVAIR 01-1A-505-1, WP 016 00.
Ensure 0.012 inch dimension is
Outer
4. Slide outer contact body over center
Ferrule
Shield
contact until bottomed.
5. Slide ferrule into the center contact.
Solder
6. Solder outer contact, ferrule and cable
in accordance with NAVAIR 01-1A-505-
1, WP 016 00. 7. Insert contact into
connector insert using tools in Table 3.
Figure 32. 617160 and 617060 Coaxial Contact Buildup