1. Strip cable to dimensions shown, IAW
(5 mm)
NAVAIR 01-1A-505-1 WP 009 00.
Crimp Sleeve
(Ferrule)
Cable Shield
0.035"
0.9 mm
2. Slide crimp sleeve (ferrule) on the cable.
3. Slide Crimp Barrel under cable shielding.
4. Strip center insulation. Ensure 0.035
inches of center insulator remains past crimp
barrel.
Crimp
Barrel
Center conductor visible in center
contact inspection hole.
5. Slide inner conductor in the center contact
Center
Crimp Sleeve
Shield
Contact
(Ferrule)
until bottomed. Ensure center conductor is
visible in the contact hole.
6. Crimp center contact using tools in Table 3
and NAVAIR 01-1A-505-1, WP 013 00.
7. Slide the crimp sleeve (ferrule) till it butts
against the crimp barrel.
Crimp Sleeve (Ferrule) butted
against crimp barrel.
Crimp Sleeve
Outer Contact
(Ferrule)
Cable
8. Slide outer contact body over center
contact sub-assembly till seated against the
crimp sleeve.
9. Crimp outer contact body in the designated
area using tools in Table 3 and NAVAIR 01-
1A-505-1, WP 013 00.
Designated
Crimp Area
Figure 33. 617102 and 617002 Coaxial Contact Buildup