NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
014 02
1 September 2011
Page 32
1. For non-environmental contact
0.787"
(620165XXX) slide alignment boot over
(20 mm)
cable. For environmental contact
(620165XXX) slide alignment boot equipped
with its sealing boot over cable. Be careful to
not damage the sealing boot while sliding it
Alignment
on the cable jacket.
Boot
2. Strip outer cable jacket to dimensions
shown, IAW NAVAIR 01-1A-505-1 WP 009
00.
Cable Jacket
0.630"
16 mm
3. Comb out exposed shield braid and cut the
rod fillers.
4. Trim both center conductors to dimension
shown.
Combed
Center
Conductor
Shield
Cable Jacket
Ferrule
5. Slide ferrule on the cable till butted against
cable jacket.
Ferrule should slide
over cable jacket and
butt at the end of the
jacket.
0.157"
Cable
0.138"
6. Fold combed shield braid over ferrule and
4.0 mm
3.5 mm
trim to dimension.
7. Trim center conductors to correct length
(0.531 inches).
8. Strip center conductors to dimensions
shown, IAW NAVAIR 01-1A-505-1 WP 009
Ferrule
00
0.531"
Shield
13.5 mm
Braid
Center
Conductors
Socket
Center conductor visible in center
Center
contact inspection hole.
Ferrule
Contact
9. Slide center contact over center conductor
till fully seated. Ensure conductor is visible in
the inspection hole.
10. Crimp center contact using tools in Table
4 and NAVAIR 01-1A-505-1, WP 013 00.
Pin
Center
Contact
Figure 35. 620165010, 620065010, 617165014 and 617065014 Twinaxial Contact Buildup (Sheet 1 of 2)