TM 1-1510-262-10
CI Display Messages
DISPLAYED
AIR
GND
MEANING
CMWS Warm-up Messages
□□□□
X
X
CI power up lamp test.
□□□□
CIV
CI software version report where X X X X is placeholder for actual version
X
X
XXXX
number, i.e., 1.01.
COMM
Indicates communication failure between CI and ECU. COMM FAIL also
X
X
FAIL
appears during the irst 30 seconds of CMWS warm up. This is normal.
During start up COMM FAIL displays for approximately 30
seconds - this is normal. If COMM FAIL display appears for
longer than 3 minutes, wait another 2 minutes before aborting
the process.
ICMD Messages
X
X
C30
Displays chaff inventory where 30 = full load.
Displays chaff inventory with low inventory caution.
X
X
CLOW
When the number of chaff cartridges is < UDM parameter threshold number,
the inventory readout alternates between quantity and "LOW".
Displays chaff inventory with depleted inventory caution.
X
X
COUT
When number of chaff drops to 0, inventory alternates between quantity 0
and "OUT".
F30
X
X
Displays lare inventory where 30 = full load.
Displays lare inventory with low inventory caution.
Total lare (sum of 206, 211, and 212 lare types) inventory is displayed. Low
decisions made on individual munitions. When individual lare type count is
X
X
FLOW
< UDM parameter threshold number for that lare type, "LOW" is displayed.
A pilot may see a display that shows 13 or 15 total lares, but still gets "LOW"
because a lare type is < threshold number. When quantity of any lare type
is < threshold number, inventory alternates between quantity and "LOW".
Displays lare inventory with depleted inventory caution.
X
X
FOUT
When number of any type of lare (i.e., M206, M211, and M212) drops to 0,
inventory readout alternates between quantity 0 and "OUT".
S1DA
(Sequencer #1, Dispenser A) Critical fault detected in Smart Dispenser A
X
X
FAIL
(Flare Dispenser). Dispenser has failed.
S1DA
(Sequencer #1, Dispenser A) Fault detected in Smart Dispenser A (Flare
X
DEGR
Dispenser). Dispenser A is operating with degraded functionality.
S1DB
(Sequencer #1, Dispenser B) Critical fault detected in Smart Dispenser B
X
X
FAIL
(Chaff Dispenser). Dispenser B has failed.
S1DB
(Sequencer #1, Dispenser B) Fault detected in Smart Dispenser B (Chaff
X
DEGR
Dispenser). Dispenser B is operating with degraded functionality.
SEQ1
X
X
Critical fault is detected in Sequencer 1. Sequencer has failed.
FAIL
4-24