TM 10-4930-351-14
0006 00
Table 1. Operator's Preventive Maintenance Checks and Services for AAFARS (Continued)
Item Interval
Location
Procedure
Not Fully Mission
No.
Capable If:
Item to Check/
Service
25
Before D1-Nozzle
Check unisex disconnect assembly (1) body for any deformation,
Any damage that
cracks, or internal gouges.
would interfere
with installation or
cause leaks.
26
Before D1-Nozzle
Check that face seal (2) is in place and not damaged.
Face seal is missing
or damaged.
27
Before D1-Nozzle
Check strainer (3) for obstructions or tears.
Strainer obstructed
or torn.
7
4
5
1
9
3
10
7
8
6
2
28
Before D1-Nozzle
Check inlet elbow (4) and regulator (5) for cracks.
Damaged enough to
cause leaking or
interfere with
operation.
29
Before D1-Nozzle
Check grounding cable assembly (6) and verify that grounding
Grounding cable,
cable, bonding plug and grounding clamp are in place and in good
condition.
grounding clamp
are broken or
missing.
30
Before D1-Nozzle
Check that handles (7) are in place and in good condition.
Handles are
missing or damaged
enough to prevent
operation.
31
Before D1-Nozzle
Inspect connection end and verify that index pins (8) and collar lock Index pins or collar
pins (9) are intact, in place and not excessively worn or damaged.
lock pins missing,
worn or damaged.
0006 00-8