TM 10-4930-351-14
0006 00
Table 1. Operator's Preventive Maintenance Checks and Services for AAFARS (Continued)
Item Interval
Location
Procedure
Not Fully Mission
No.
Capable If:
Item to Check/
Service
32
Before D1-Nozzle
Verify that all three collar lock pins (9) are intact, undamaged and
Index pins are not
are extended and engage all three cutouts in the collar and
extended to engage
physically prevent collar rotation. If the collar lock pins (9) are not
all three collar
extended and engaged in all three cutouts in the collar, the operator
cutouts.
should squeeze the lever and handle grip together while observing
the connecting end of the nozzle. This should cause the collar lock
pins (9) to spring into the cutouts in the collar.
33
Before D1-Nozzle
Attempt to open the nozzle with the lever (10).
Nozzle opens.
34
Before Pressure Control Check exterior parts for cracks and leaks. Check female coupling
Any damage that
half for missing or damaged gasket. Check for missing or damaged would cause leaks.
dust plug. Check dust cap for missing or damaged gasket.
35
Before Fuel Drum
Check the adapter assembly (1) for cracks, leaks, and damaged
Any damage that
threads.
would interfere
with installation or
causes leaks.
36
Before Fuel Drum
Check the fuel drum (2) fabrics for cuts, holes, deterioration, and
Drum has punctures
leaks. Check the metal parts for cracks, leaks, and loose capscrews. and/or excessive
No fabric cords should be showing through the rubber ream of the wear.
drum body.
1
2
37
Before TRICON
Inspect door handles and related hardware (1) for any broken welds Handle or related
Container
or defective parts. Operate handles.
hardware are
broken or if handles
will not open door.
0006 00-9