2-8.1
2-8.1
TM 55-2840-254-23
b. Check compressor housing (22)
for nicks,
chafing, and dirt or other deposits in bleed
band area. If nicks, chafing, dirt or other
deposits are found, proceed as follows:
(1) Remove compressor bleed band (Ref.
Task 2-9).
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
of contact immediately flush skin or eyes
with water for at least 15 minutes. Get
medical attention for eyes.
(2) Clean compressor housing as follows:
(a)
when
Wear gloves (E20), and clean com-
pressor housing (22). Use brush and
wiping rag (E58) dampened in dry
cleaning solvent (E17).
using compressed air for cleaning,
use approved protective equipment for
-
eyes and face. Do not use more than 30
psig air pressure. Do not direct air toward
yourself or another person. Failure to
comply could result in injury to eyes or
skin. In case of injury, get medical atten-
tion.
(b) Wear goggles. Blow dry compressor
housing (22) using clean, dry com-
pressed air.
GO TO NEXT PAGE
2-40.9
Change 5