TM 55-2840-254-23
2-8 ADJUST INTERSTAGE AIR-BLEED ACTUATOR (WITHOUT WATER WASH KIT
2-8
P/N 2-200-071-54 INSTALLED)
INITIAL SETUP
Tools:
Powerplant Mechanics Tool Kit,
NSN 5180-00-323-4944
Technical Inspection Tool Kit,
NSN 5180-00-323-5114
Compressed Air Source
Torque Wrench, 30-150 Inch-Pounds
Materials:
Carborundum Stone (E10)
Crocus Cloth (E15)
Dry Cleaning Solvent (E17)
Gloves (E20)
Lockwire (E29)
Wiping Rag (E58)
Personnel Required:
68B10 Aircraft Powerplant Repairer
68B30 Aircraft Powerplant Inspector
References:
Task 2-9
Task 2-13
Equipment Condition:
Oil Cooler Assembly Removed (Task 8-5)
General Safety Instructions:
The ignition exciter stores very
high and possibly fatal voltage.
Use extreme care when working
around ignition exciter. Serious
injury could result if exciter is
accidentally grounded. Do not
probe inside of output receptacles
with fingers or metal object. Dis-
charge exciter only with insulated
screwdriver. In case of shock or
injury, get medical attention.
2-28.7/(2-28.8 blank)