TM 55-2840-254-23
2-7.1 INSTALL INTERSTAGE AIR-BLEED ACTUATOR (WITH WATER WASH KIT
2-7.1
P/N 2-200-071-54 INSTALLED) (Continued)
7. Connect tube assembly(18) to union (19).
8. Install tee (20) on reducer (21).
9. Install nut (22) on tee (23). Install packing
(24) on tee (23). Position nut to make sure
packing is in groove between two sets of
threads on tee.
10. Install tee (23) into air-bleed port (25).
11. Adjust interstate air-bleed actuator (Ref.
Task 2-8, steps 6. thru 17.)
GO TO NEXT PAGE
2-28.4 Change 5