TM 55-2840-254-23
2-8 ADJUST INTERSTAGE AIR-BLEED ACTUATOR (WITHOUT WATER WASH KIT
2-8
P/N 2-200-071-54 INSTALLED) (Continued)
7. Connect air pressure hose from air compre-
sor to tee (14). Apply 60 psig, air pressure.
7.1 .Visually check that there is no piston(13)
movement in the open position.
8. Activate piston (13) to closed position by
placing finger over union (15).
GO TO NEXT PAGE
Change 5
2 - 3
1