TM 55-4920-328-13
Figure 6-7. Oil Filter.
6-26. Inspection Requirements.
Inspect the components comprising METS, using
the instructions contained in table 6-4. If a component
or detail part is found defective, repair or install a new
unit as outlined in this section.
Table 6-4. Inspection Requirements
COMPONENT
INSPECT FOR
INTERVAL
Electrical Cable
Integrity of pin to wire
30 days
Assemblies
connections, broken or
damaged shells and strain
reliefs, burned or frayed
insulation, evidence of wire
breaks or shorts, security
and legibility of cable
marking sleeves
Power Supplies,
Security of electrical con-
30 days
Terminal Boards and
nections, evidence of wire
Lugs, Monitor Alarm
breaks or shorts, burned or
Assembly, and Panel
damaged insulation and re-
Mounted Electrical
sistor boards, missing or
Units
loose attaching parts, and
security of controls
Tube Assemblies
Dents, cracks, or sharp
90 days
bends, evidence of leakage
around sleeves and B-nuts,
cracked fittings, security
of attachment of jamnuts
and clamps
6-20