Figure 36. 617190010 and 167090010 Triaxial Contact Buildup (Sheet 1 of 3)
Figure 36. 617190010 and 167090010 Triaxial Contact Buildup (Buildup (Sheet 3)

Installation and Repair Practices Volume III - Aircract Rectangular Electrical Connectors and Accessories
Page Navigation
  362    363    364    365    366  367  368    369    370    371    372  
img
NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
014 02
1 September 2011
Page 35
Dielectric
Insulator
10. Slide ferrule over dielectric insulator till
fully seated.
Shield
Ferrule
Braid
11. Slide the center insulator over center contact till seated.
12. Slide intermediate contact over center insulator.
13. Put the second conductor into the intermediate contact slot.
14. Slide the ferrule over second conductor and crimp using tools in Table 5 and NAVAIR 01-1A-505-1,
WP 013 00. Ensure second conductor faces crimp die flat.