Cable Jacket
0.787"
20 mm
1. Strip outer cable jacket to dimensions
shown, IAW NAVAIR 01-1A-505-1 WP 009
00.
Cable Jacket
0.591"
15 mm
2. Comb out exposed shield braid.
3. Trim both center conductors to dimension
shown.
4. Fold shield back over center conductors
and lightly twist to facilitate sliding ferrule on
Combed
to cable.
Center
Ferrule
Shield
Conductor
0.197"
5 mm
Cable
0.118"
Jacket
5. Slide the ferrule on the cable till butted
3 mm
against cable jacket.
6. Fold combed shield braid over shield crimp
sleeve and trim to dimension.
7. Trim center conductors to correct length
(0.197 inches).
2nd Conductor
0.276"
8. Strip center conductors to dimensions
(White)
7 mm
Ferrule should slide
Intermediate
shown, IAW NAVAIR 01-1A-505-1 WP 009
over cable jacket and
Contact
00
1st Conductor
butt at the end of the
(Blue)
jacket.
Center
Contact
9. Slide the dielectric insulator on the first
Shield
Second Conductor
conductor. Ensure second conductor is in slot
Crimp
in Insulator Slot
Sleeve
on the outside of the insulator
10. Slide center contact over center
conductor till fully seated. Ensure conductor
is visible in the inspection hole and that
contact and dielectric insulator are fully
Center
seated.
Contact
Dielectric
11. Crimp center contact using tools in Table
Cable Shield
Insulator
5 and NAVAIR 01-1A-505-1, WP 013 00.
Center conductor visible in center
contact inspection hole.
Figure 37. 617190012 and 167090012 Triaxial Contact Buildup (Sheet 1 of 2)